RailConX ECS Ethernet Consist Switch
Railway Ethernet Consist Switch for TCMS, passenger information and onboard monitoring within the Ethernet Consist Network (ECN). Prototype testing in progress.
RailConX ECS
The RailConX ECS (Ethernet Consist Switch) connects onboard equipment within an Ethernet Consist Network (ECN). It provides switching for Train Control and Management Systems (TCMS), passenger information and onboard monitoring, with support for IEC 61375-3-4 consist networking. The platform is currently undergoing prototype testing.
Key Features
Interfaces
Use Case

Railway Ethernet switching within the consist
An Ethernet Consist Switch connects onboard devices within the Ethernet Consist Network (ECN). IEC 61375-3-4 addresses this consist network; an Ethernet Train Backbone Node connects consist networks across the train. Specify Layer 2 switching, VLAN, management and redundancy requirements for the project. Managed or unmanaged operation must be confirmed for the selected ECS configuration. RailConX ECS is undergoing prototype testing.
EN 50155, IEC 60571 and project qualification
EN 50155 and IEC 60571 address electronic equipment used on rolling stock. IEC 61375 addresses train communication networks. Agree the applicable editions and request certificates or test reports for the exact hardware and software configuration. Environmental qualification does not establish a Safety Integrity Level (SIL); safety-related control and I/O need their own assessment and evidence.